Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Pediatr ; 12: 1302383, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38550630

RESUMO

Introduction: Assessment of myocardial function through speckle tracking echocardiography (STE) can bring benefits to conventional echocardiography in premature newborns, a particular vulnerable group in terms of adaptation to extra-uterine life. Furthermore, it represents a non-invasive imagistic method which can guide therapeutic approach in the hemodynamically unstable newborn. This study aims to highlight the particularities of myocardial function in late premature newborns, by conducting a comparison with a group of healthy neonates, by using STE. Methods: Conducted over a timespan of two years, this prospective study enrolled 64 term neonates and 21 premature newborns, with gestational ages ranging between 28 and 36 weeks, who prior to discharge underwent a cardiac ultrasound, involving two-dimensional image acquisitions of the apical four-chamber view of both ventricles. Afterwards, the images were offline analyzed, by using the autostrain function. Results: After segmental strain analysis, no significant discrepancies between the two groups in terms of interventricular values were found. However, left ventricle and right ventricle strain measurements differed significantly (p < 0.01), for each of the analyzed segments (basal, medial or apical). Moreover, a linear increase in interventricular (IV) basal strain with corrected gestational age progression was noted (p = 0.04). Peak global longitudinal strain (pGLS) and EF were similar between the two study groups. Premature newborns presented significantly more negative mean values of right ventricular free wall longitudinal strain (RVFWSL), (-24.19 ± 4.95 vs. -18.05 ± 5.88, p < 0.01) and of right ventricle global four chamber longitudinal strain (RV4CSL), (-19.71 ± 3.62 vs. -15.46 ± 5.59, p < 0.01), when compared to term neonates. Conclusions: The 2D STE is a reliable method for cardiac assessment of late preterm newborns. The evaluation of two-dimensional global longitudinal LV and RV strains might represent a useful tool in clinical practice. A better response of the right ventricle to the longitudinal deformation within premature neonates was noted. Thus, this study facilitates the identification of accurate reference values for this particular population segment, which will enable the evaluation of ventricular function in premature newborns with concurring disorders. Future longitudinal studies, assessing the fetal heart, could provide more insight into the development of myocardial function.

2.
Med Ultrason ; 25(2): 168-174, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37369048

RESUMO

AIMS: Measurement of myocardial strain using 2D speckle-tracking echocardiography can successfully quantify ventricular function, being considered superior to conventional echocardiography. This study aimed to establish reference intervals, interobserver agreements and reliability of two fetal echocardiographic parameters which reflect left ventricular myocardial function, left ventricular apical 4 chamber endo peak strain (AP4pLS) and ejection fraction (EF). MATERIAL AND METHODS: We conducted a prospective study on 103 healthy fetuses. In each case, cardiac ultrasound images obtained were stored and afterwards were subject to offline 2D speckle-tracking echocardiographic analyses. In 15 randomly chosen subjects a second examiner also carried out an offline analysis of the 4-chamber view and the archived images, in order to assess inter-observer reproducibility and agreement level. Our study group was sub-divided into four different gestational age groups. RESULTS: Reference ranges were established for the two measured parameters, AP4pLS and EF, which did not differ significantly between four different gestational age groups (p=0.98 and p=0.64) and neither correlated with gestational age progression (p=0.37 and p=0.08). An excellent level of agreement between the two examiners was found for the echocardiographic measurements, expressed through an intra-class correlation coefficient (ICC) value of 0.85 (0.62-0.94 for 95%CI) for AP4pLS and 0.78 (0.47- 0.92 for 95% CI) for EF. CONCLUSIONS: Speckle tracking AP4pLS and EF parameters are useful for assessment of ventricular myocardial function in healthy fetuses and can be reliably reproduced by two different skilled examiners. Further studies conducted on larger populations are required to standardize reference values of fetal speckle-tracking measurements.


Assuntos
Ecocardiografia , Função Ventricular Esquerda , Humanos , Reprodutibilidade dos Testes , Estudos Prospectivos , Variações Dependentes do Observador , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem
3.
Artigo em Inglês | MEDLINE | ID: mdl-35886472

RESUMO

Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal and regional strain measurements. A total of 127 full-term newborns were examined to be included in the study, of which 103 were analyzed. We used two-dimensional acquisitions from apical four-chamber view of both ventricles and analyzed the autostrain function offline. We obtained interobserver agreement between the two observers ranging from good to excellent for all speckle-tracking parameters except for the strain of the medial portion of the left ventricle (LV) lateral wall and the strain measured on the basal portion of the inter-ventricular septum, which reflected a fair interobserver reproducibility (ICC = 0.52, 95% IC: 0.22-0.72 and ICC = 0.43, 95% IC: 0.12-0.67, respectively). The reference values obtained for the LV peak longitudinal strain were between -24.65 and -14.62, those for the right ventricle (RV) free wall were from -28.69 to -10.68, and those for the RV global four-chamber were from -22.30 to -11.37. In conclusion, two-dimensional peak longitudinal LV and RV strains are reproducible with good to excellent agreement and may represent a possible alternative for the cardiac assessment of healthy newborns in the clinical practice.


Assuntos
Ecocardiografia , Ventrículos do Coração , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes
4.
J Clin Med ; 11(3)2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35160256

RESUMO

Sustained fetal tachycardias are rare but represent a high risk of mortality and morbidity. Consensus has yet to be found regarding their optimal management. The aim of this narrative review is to summarize the data available in the current literature regarding the efficacy and safety of medications used in the management of intrauterine tachyarrhythmias and to provide possible treatment protocols. In this review, we would like to emphasize the importance of a thorough evaluation of both the fetus and the mother, prior to transplacental antiarrhythmic drug initiation. Factors such as the hemodynamic status of the fetus, possible mechanisms of fetal arrhythmia, and concomitant maternal conditions are of primordial importance. As a possible treatment protocol, we would like to recommend the following: due to the risk of sustained supraventricular tachycardia (SVT), fetuses with frequent premature atrial beats should be evaluated more frequently by echocardiography. A careful hemodynamic evaluation of a fetus with tachycardia is primordial in forestalling the appearance of hydrops. In the case of atrial flutter (AFL), sotalol therapy could represent a first choice, whereas when dealing with SVT patients, flecainide should be considered, especially for hydropic patients. These data require consolidation through larger scale, non-randomized studies and should be handled with caution.

5.
J Pers Med ; 12(1)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35055372

RESUMO

Our aim was to compare the global longitudinal and regional biventricular strain between infants with severe and critical pulmonary stenosis (PS), and controls; to compare pre- and post-procedural strain values in infants with severe and critical PS; and to assess the correlations between echocardiographic strain and conventional parameters. We conducted a retrospective single-center study. The comparisons of echocardiographic variables were performed using separate linear mixed models. The overall mean right ventricle (RV) regional strains measured before intervention in PS patients was significantly different when compared to the control group (p = 0.0324). We found a significant change in the left ventricle, RV, and inter-ventricular septum strain (IVS) values from basal to apical location (p < 0.05). IVS strain values showed a higher decrease in mean strain values from basal to apical in PS patients. There was no significant difference in means of baseline and post-interventional strain values in PS patients (p > 0.05). Following the strain analysis in patients with PS, we obtained statistically significant changes in the RV global-4-chamber longitudinal strain (RV4C). The RV4C, which quantifies the longitudinal strain to the entire RV, can be used in current clinical practice for the evaluation of RV function in infants with severe and critical PS. The longitudinal and segmental strain capture the pathological changes in the IVS, modifications that cannot be highlighted through a classical echocardiographic evaluation.

6.
Artigo em Inglês | MEDLINE | ID: mdl-36612992

RESUMO

The transposition of great arteries (TGA) is one of the most frequent and severe congenital heart diseases. After newborn stabilization and while pending surgical correction, echocardiographic monitoring with a careful evaluation of left ventricle (LV) performance is warranted. In this study, our objectives were (i) to compare myocardial function, assessed via speckle-tracking echocardiography, between neonates with TGA and neonates without TGA and (ii) to identify a strain parameter with a good discriminatory ability for TGA. We conducted a retrospective, single-center study. A total of 90 neonates were examined, of whom 66 were included (16 comprised the TGA group and 50 comprised the control group). The results of a bivariate analysis showed that classic echocardiography parameters displayed no significant differences between the two studied groups (p = 0.785 for EF, p = 0.286 for MAPSE and p = 0.315 for TAPSE). We found a statistically significant difference between the two groups for the mean values of the LVpGLS parameter (adjusted p = 0.0047), with impaired LV myocardium function being observed in the TGA group after adjusting for other covariates. Regarding segmental strain, the mean medial and apical inter-ventricular septum strain values were found to be significantly lower in the neonates with TGA than in the controls (95% CI for difference in means: [-6.45, -0.65], [-8.56, -1.97]). The results of an ROC analysis showed that LVpGLS had a significant ability to differentiate between neonates with TGA and controls (AUC = 0.712, 95% CI: [0.52, 0.903], p = 0.011). In conclusion, LVpGLS is a parameter with a significant discriminatory ability for LV dysfunction, and it is useful in the evaluation of ventricular myocardial function in newborns with TGA.


Assuntos
Ventrículos do Coração , Transposição dos Grandes Vasos , Humanos , Recém-Nascido , Ventrículos do Coração/diagnóstico por imagem , Estudos Retrospectivos , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Ecocardiografia/métodos , Função Ventricular Esquerda
7.
Artigo em Inglês | MEDLINE | ID: mdl-34886523

RESUMO

The clinical course of COVID in the pediatric population is considered to be much milder when compared to adults; however, the occurrence of severe and fatal forms of the disease in children is non-negligible, especially in patients with comorbidities such as prematurity or cardiac disease. We report a case of a newborn with sotalol-controlled fetal ventricular tachycardia, who was postnatally diagnosed with COVID infection. The myocardial injury was sustained on the basis of pericardial effusion, left ventricular dysfunction, rapid progression to coronary artery dilation, and an arrhythmic storm. We believe that, in our case, there is a significant overlap between fetal ventricular tachycardia, associated with impaired left ventricular function, and COVID infection, diagnosed after birth; both factors contribute to the myocardial dysfunction with a fulminant clinical evolution. To our knowledge, this is the first case describing neonatal myocardial dysfunction associated with SARS-CoV infection complicating the clinical course of rare fetal tachyarrhythmia.


Assuntos
COVID-19 , Miocardite , Derrame Pericárdico , Taquicardia Ventricular , Criança , Humanos , Recém-Nascido , SARS-CoV-2 , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia
8.
J Clin Med ; 10(19)2021 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-34640597

RESUMO

Our objectives are to compare speckle-tracking peak global longitudinal (pGLS) and regional strain values in neonates with coarctation of aorta (CoA) and control groups. Echocardiographic parameters measured by speckle-tracking were studied in a retrospective single-center study. A comparison of pGLS and segmental deformation between neonates with CoA and control group was performed using a three-way mixed ANOVA model. There was a significant difference in the means of segmental strain values between CoA and control group at the apical (p = 0.018) and basal segments (p = 0.031) of the interventricular septum and at the apical segment (p = 0.026) of the left ventricle (LV). After correcting for multiple comparisons, the results had a tendency toward statistical significance (adjusted-p < 0.10). There was significant difference in the mean values of pGLS [F(1, 39) = 7.61, p = 0.009, adjusted p = 0.018] between the studied groups. The results of ROC analysis showed that a cut-off value of -16.60% for pGLS provided an estimated sensitivity of 92.31% (95% CI: [63.97, 99.81]) and 71.43% specificity (95% CI: [51.33, 86.78]) for the diagnosis of CoA in neonates (AUC = 0.794, 95% CI: [0.66, 0.93]). pGLS can be regarded as a feasible and reproducible parameter reflecting LV dysfunction in newborns with CoA when compared to newborns with a false-positive diagnosis.

9.
Med Ultrason ; 23(2): 188-193, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-33626113

RESUMO

AIM: Congenital atrioventricular block (CAVB) is an immunological condition, secondary to the transfer of maternal Ig G antibodies from seropositive mothers. Although the presence of these antibodies is high among pregnant women, the preva-lence of this fetal pathology is low. The aim of this paper is to analyze a series of cases with intrauterine diagnosis of CAVB and to present their follow-up protocol. MATERIAL AND METHOD: In the period between 2013-2020, five fetuses were diagnosed and followed up in the Pediatric Cardiology Clinic. In each of the cases, assessment of the hemodynamic status was done by calculation of the fetal cardiovascular profile score (CVPS). In the last cases the follow-up protocol was supplemented with longitudinal speckle tracking evaluation of the ventricular function. RESULTS: In the present series, intrauterine death occurred in one case; in another case resumption of atrioventricular conduction was observed. Epicardial pacemaker implantation was required in three of the patients. CONCLUSION: Completing the evaluation of ventricular function with the longitudinal speckle tracking method in fetuses and newborn patients with congenital atrioventricular block may play an important role in establish-ing therapeutic behavior.


Assuntos
Bloqueio Atrioventricular , Bloqueio Atrioventricular/diagnóstico por imagem , Bloqueio Atrioventricular/terapia , Feminino , Humanos , Recém-Nascido , Marca-Passo Artificial , Gravidez , Diagnóstico Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...